RadiSys ATCA-5400 RTM Especificaciones Pagina 93

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 174
  • Tabla de contenidos
  • SOLUCIÓN DE PROBLEMAS
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 92
A
Electromagnetic compatibility (EMC)
93
Electromagnetic compatibility (EMC)
TheESD,EMC,andImmunityspecificationsaremeasuredwithambienttemperature
between20Cand30Candrelativehumiditybetween30%and50%.
Table 29. Electromagnetic compatibility (EMC)
Characteristic State Standard and criteria
Emissions Radiated emissions Operating FCC Part 15,
Class A requirement for chassis/system level,
Class A with 6db margin objective for blade
EN 55022: 2006,
Class A requirement for chassis/system level,
Class A with 6db margin objective for blade
Conducted emissions Operating FCC Part 15, Class A with 6db margin
EN 55022: 2006, Class A with 6db margin
Immunity ESD Operating EN 61000-4-2
8 KV direct contact, performance criteria B
15 KV air discharge, performance criteria C
Radiated Operating EN 61000-4-3
10 V/m, 30 MHz–10 GHz, 80% AM
Performance criteria A
Fast transient/burst Operating EN 61000-4-4
0.5 kV, 5/50 ns, 5 kHz repetition frequency
Performance criteria B
Surge voltages Operating EN 61000-4-5
Data ports: 1 kV, 1.2/50 s or 8/20 s
DC power port: 0.5 kV, 1.2/50 s or 8/20 s
Performance criteria B
Conducted Operating EN 61000-4-6
0.15–80 MHz, 3 V, 80% AM
Performance criteria A
Magnetic field immunity Operating EN 61000-4-8
50 Hz / 1 A/m
Performance criteria A