3
Issues resolved in this release
eepupdate.sh is not compatible with the Fabric Ethernet controller on the ATCA-4500
The eepupdate.sh tool is used to update the EEPROM device attached to Ethernet controllers.
Versions of this tool prior to version 1.11 have compatibility problems with the 10 Gb Fabric
Ethernet interface. If older tools are used, the update will be incomplete and the MAC addresses
of the 10 Gb Fabric Ethernet interfaces will be set to 00:00:50:4E:88:86 and
00:00:50:4E:88:87.
Use the eepupdate_oplin.sh tool to update the EEPROM on the Fabric Ethernet device.
Resolution: Use the new tool eepupdate_oplin.sh to upgrade the EEPROM on the
Fabric Ethernet device. If you have used a previous tool on your ATCA-4500
and the MAC addresses of the 10 Gb Fabric Ethernet interfaces match those
above, please contact RadiSys for instructions on correcting the problem.
Issue No: RSYS00049074
IPMI driver fails to load on startup with MontaVista 5 em64t version 2.3.20
The IPMI driver fails to load on startup after installing MontaVista 5 em64t and the 2.3.20 RPMs
on the CPM.
This is an issue with the MV module-init-tools-3.2.2-1.0.0.0900195 package. MontaVista has
released package updates to resolve the issue.
Resolution: Acquire these two MontaVista package updates:
depmod-3.2.2-1.0.1.0901158.x86_em64t.mvl from MontaVista
module-init-tools-3.2.2-1.0.1.0901158.x86_em64t.mvl
Issue No: RSYS00048203