Known product limitations
8
rsysbflash and rsys-update for Linux should not be used with any BIOS prior to 01.01.29
The rsysbflash utility may hang the system if it is used on any BIOS prior to 01.01.29. A BIOS
update is required to enable rsysbflash. The rsys-update utility depends on rsysbflash, so
rsys-update will also fail on CPMs where the BIOS version is prior to 01.01.29.
Workaround: Update the BIOS to 01.01.29 or later using the EFI shell, or use afulnx
2.29b6 or later.
Resolution: This issue will be addressed in a future release.
Issue No: RSYS00048645
BIOS shell displays "Cannot read from file - Device Error" when updating to BIOS 01.01.30
If the BIOS is updated using the update.nsh script, the EFI shell returns "Shell: Cannot read from
file - Device Error" after completing the flashing process. This only occurs when the BIOS is
updated to 01.01.30.
Workaround: Manually execute the following command to update the BIOS:
afuefix64.efi BIOS.ROM /p /b /x
Resolution: This issue may be addressed in a future release.
Issue No: RSYS00048923
BIOS intermittently shows "Current BIOS Flash" as "Unknown" in the BIOS boot menu
"Current BIOS Flash" in the BIOS menu intermittently shows "Unknown." The situation occurs
because the IPMC is busy with other management events and is not able to complete the IPMI
command successfully when the BIOS queries the active boot flash.
Workaround: Manually query the booting BIOS flash using the OEM IPMI command (Get
Active Boot Flash command).
Resolution: This issue may be addressed in a future release.
Issue No: RSYS00048924
Documented RTM Outlet Temp sensor LC and LNC values do not match the measured values
The documented LC and LNC values for the Outlet Temp sensor on the ATCA-5400 RTM do not
match the actual measured values. The ATCA-5400 RTM Reference lists LC with a value of 1
and LNC with a value of 2 for the Outlet Temp sensor. The measured value for LC is 1.96 and
the measured value for LNC is 2.94.
Workaround: None.
Resolution: This issue will be addressed in a future release.
Issue No: RSYS00048969